SMA Energy Meter Binding

This Binding is used to display the measured values of a SMA Energy Meter device. It shows active, reactive, and apparent power and energy, plus power factor, current, voltage, frequency, and version values published by the meter.
Supported Things
This Binding supports SMA Energy Meter devices.
Discovery
The Energy Meter is discovered by receiving data on the default multicast IP address.
Binding Configuration
No binding configuration required.
Thing Configuration
Usually no manual configuration is required, as the multicast IP address and the port remain on their factory set values. Optionally, a refresh interval (in seconds) can be defined.
| Parameter | Name | Description | Required | Default |
|---|---|---|---|---|
serialNumber | Serial number | Decimal serial number of a meter; hexadecimal remains supported for compatibility. | yes | |
mcastGroup | Multicast Group | Multicast group used by meter. | yes | 239.12.255.254 |
port | Port | Port number used by meter. | no | 9522 |
pollingPeriod | Polling Period | Polling period used to publish meter reading (in seconds). | no | 30 |
The polling period parameter is used to trigger readout of meter. In case if two consecutive readout attempts fail Thing will report offline status.
Channels
| Channel | Description |
|---|---|
| activePowerIn / activePowerOut | Purchased and grid feed-in active power |
| activePowerInL1 / activePowerOutL1 | Purchased and grid feed-in active power L1 |
| activePowerInL2 / activePowerOutL2 | Purchased and grid feed-in active power L2 |
| activePowerInL3 / activePowerOutL3 | Purchased and grid feed-in active power L3 |
| activeEnergyIn / activeEnergyOut | Purchased and grid feed-in active energy |
| activeEnergyInL1 / activeEnergyOutL1 | Purchased and grid feed-in active energy L1 |
| activeEnergyInL2 / activeEnergyOutL2 | Purchased and grid feed-in active energy L2 |
| activeEnergyInL3 / activeEnergyOutL3 | Purchased and grid feed-in active energy L3 |
| reactivePowerIn / reactivePowerOut | Purchased and grid feed-in reactive power |
| reactivePowerInL1 / reactivePowerOutL1 | Purchased and grid feed-in reactive power L1 |
| reactivePowerInL2 / reactivePowerOutL2 | Purchased and grid feed-in reactive power L2 |
| reactivePowerInL3 / reactivePowerOutL3 | Purchased and grid feed-in reactive power L3 |
| reactiveEnergyIn / reactiveEnergyOut | Purchased and grid feed-in reactive energy |
| reactiveEnergyInL1 / reactiveEnergyOutL1 | Purchased and grid feed-in reactive energy L1 |
| reactiveEnergyInL2 / reactiveEnergyOutL2 | Purchased and grid feed-in reactive energy L2 |
| reactiveEnergyInL3 / reactiveEnergyOutL3 | Purchased and grid feed-in reactive energy L3 |
| apparentPowerIn / apparentPowerOut | Purchased and grid feed-in apparent power |
| apparentPowerInL1 / apparentPowerOutL1 | Purchased and grid feed-in apparent power L1 |
| apparentPowerInL2 / apparentPowerOutL2 | Purchased and grid feed-in apparent power L2 |
| apparentPowerInL3 / apparentPowerOutL3 | Purchased and grid feed-in apparent power L3 |
| apparentEnergyIn / apparentEnergyOut | Purchased and grid feed-in apparent energy |
| apparentEnergyInL1 / apparentEnergyOutL1 | Purchased and grid feed-in apparent energy L1 |
| apparentEnergyInL2 / apparentEnergyOutL2 | Purchased and grid feed-in apparent energy L2 |
| apparentEnergyInL3 / apparentEnergyOutL3 | Purchased and grid feed-in apparent energy L3 |
| powerFactor / powerFactorL1 / powerFactorL2 / powerFactorL3 | Power factor total and per phase |
| currentL1 / currentL2 / currentL3 | Current per phase |
| voltageL1 / voltageL2 / voltageL3 | Voltage per phase |
| frequency | Grid frequency |
| version | Device version |
Older channel links using the former powerIn / energyIn names are migrated automatically through the binding update description.
Full example
N/A