SMA Energy Meter Binding ​

This Binding is used to display the measured values of a SMA Energy Meter device. It shows active, reactive, and apparent power and energy, plus power factor, current, voltage, frequency, and version values published by the meter.

Supported Things ​

This Binding supports SMA Energy Meter devices.

Discovery ​

The Energy Meter is discovered by receiving data on the default multicast IP address.

Binding Configuration ​

No binding configuration required.

Thing Configuration ​

Usually no manual configuration is required, as the multicast IP address and the port remain on their factory set values. Optionally, a refresh interval (in seconds) can be defined.

ParameterNameDescriptionRequiredDefault
serialNumberSerial numberDecimal serial number of a meter; hexadecimal remains supported for compatibility.yes
mcastGroupMulticast GroupMulticast group used by meter.yes239.12.255.254
portPortPort number used by meter.no9522
pollingPeriodPolling PeriodPolling period used to publish meter reading (in seconds).no30

The polling period parameter is used to trigger readout of meter. In case if two consecutive readout attempts fail Thing will report offline status.

Channels ​

ChannelDescription
activePowerIn / activePowerOutPurchased and grid feed-in active power
activePowerInL1 / activePowerOutL1Purchased and grid feed-in active power L1
activePowerInL2 / activePowerOutL2Purchased and grid feed-in active power L2
activePowerInL3 / activePowerOutL3Purchased and grid feed-in active power L3
activeEnergyIn / activeEnergyOutPurchased and grid feed-in active energy
activeEnergyInL1 / activeEnergyOutL1Purchased and grid feed-in active energy L1
activeEnergyInL2 / activeEnergyOutL2Purchased and grid feed-in active energy L2
activeEnergyInL3 / activeEnergyOutL3Purchased and grid feed-in active energy L3
reactivePowerIn / reactivePowerOutPurchased and grid feed-in reactive power
reactivePowerInL1 / reactivePowerOutL1Purchased and grid feed-in reactive power L1
reactivePowerInL2 / reactivePowerOutL2Purchased and grid feed-in reactive power L2
reactivePowerInL3 / reactivePowerOutL3Purchased and grid feed-in reactive power L3
reactiveEnergyIn / reactiveEnergyOutPurchased and grid feed-in reactive energy
reactiveEnergyInL1 / reactiveEnergyOutL1Purchased and grid feed-in reactive energy L1
reactiveEnergyInL2 / reactiveEnergyOutL2Purchased and grid feed-in reactive energy L2
reactiveEnergyInL3 / reactiveEnergyOutL3Purchased and grid feed-in reactive energy L3
apparentPowerIn / apparentPowerOutPurchased and grid feed-in apparent power
apparentPowerInL1 / apparentPowerOutL1Purchased and grid feed-in apparent power L1
apparentPowerInL2 / apparentPowerOutL2Purchased and grid feed-in apparent power L2
apparentPowerInL3 / apparentPowerOutL3Purchased and grid feed-in apparent power L3
apparentEnergyIn / apparentEnergyOutPurchased and grid feed-in apparent energy
apparentEnergyInL1 / apparentEnergyOutL1Purchased and grid feed-in apparent energy L1
apparentEnergyInL2 / apparentEnergyOutL2Purchased and grid feed-in apparent energy L2
apparentEnergyInL3 / apparentEnergyOutL3Purchased and grid feed-in apparent energy L3
powerFactor / powerFactorL1 / powerFactorL2 / powerFactorL3Power factor total and per phase
currentL1 / currentL2 / currentL3Current per phase
voltageL1 / voltageL2 / voltageL3Voltage per phase
frequencyGrid frequency
versionDevice version

Older channel links using the former powerIn / energyIn names are migrated automatically through the binding update description.

Full example ​

N/A