Enphase Binding ​

This is the binding for the Enphase Envoy Solar Panel gateway. The binding uses the local API of the Envoy gateway. Some calls can be made without authentication and some use a user name and password. The default user name is envoy and the default password is the last 6 numbers of the serial number. The Envoy gateway updates the data every 5 minutes. Therefore using a refresh rate shorter doesn't provide more information.

Supported Things ​

The follow things are supported:

  • envoy The Envoy gateway thing, which is a bridge thing.
  • inverter An Enphase micro inverter connected to a solar panel.
  • relay An Enphase relay.
  • battery An Enphase IQ Battery (Encharge). Only available on Envoy gateways with version 7 firmware and higher.

Not all Envoy gateways support all channels and things. Therefore some data on inverters and the relay may not be available. The binding auto detects which data is available and will report this in the log on initialization of the gateway bridge.

Discovery ​

The binding can discover Envoy gateways, micro inverters, relays and IQ Batteries. If login access is needed the Bridge envoy needs to be configured after discovering and adding before other things can be discovered. In that case, after configuring the login, run discovery again.

Thing Configuration ​

Bridge configuration ​

Depending on the software version of the Envoy gateway thing envoy there are different configuration options needed. Newer versions of the Envoy software (> version 7) require a different authentication method. Because the configuration is different, different bridge things are available.

The following options are relevant for all envoy versions:

parameterrequireddescription
serialNumberyesThe serial number of the Envoy gateway which can be found on the gateway
hostnamenoThe host name/ip address of the Envoy gateway. Leave empty to auto detect
refreshnoPeriod between data updates. The default is the same 5 minutes the data is actually refreshed on the Envoy

Envoy below version 7 ​

For Envoy versions below 7 has the following authentication configuration options are relevant:

parameterrequireddescription
usernamenoThe user name to the Envoy gateway. Leave empty when using the default user name
passwordnoThe password to the Envoy gateway. Leave empty when using the default password

Envoy from version 7 ​

For Envoy versions 7 and newer has the following authentication configuration options are relevant:

parameterrequireddescription
autoJwtyesSpecify if the JWT access token should be obtained by logging in or if the jwt is provided manually
usernameyes/noThe user name to the Entrez server. Required if auto Jwt is true
passwordyes/noThe password to the Entrez server. Required if auto Jwt is true
siteNameyes/noThe name of the site. Can be found above the Site Id in the Enphase app. Required when autoJwt is true
jwtyes/noThe jwt is required if autoJWT is false, if it's true jwt is not used

Thing configuration ​

The micro inverter inverter, relay and battery things have only 1 parameter:

parameterrequireddescription
serialNumberyesThe serial number of the device

Channels ​

The envoy thing has can show both production as well as consumption data. There are channel groups for production and consumption data. The consumption data is only available if the gateway reports this. An example of a production channel name is: production#wattsNow.

channeltypedescription
wattHoursTodayNumber:EnergyWatt hours produced today
wattHoursSevenDaysNumber:EnergyWatt hours produced the last 7 days
wattHoursLifetimeNumber:EnergyWatt hours produced over the lifetime
wattsNowNumber:PowerLatest watts produced

On Envoy gateways with version 7 firmware and higher the consumption data is read from the metering endpoint. This endpoint only provides the instantaneous wattsNow value (and wattHoursLifetime when a total-consumption meter is present). The wattHoursToday and wattHoursSevenDays consumption channels are not available from this endpoint and stay undefined.

When IQ Batteries are installed, the storage channel group shows the aggregated data of all batteries. This data is only available on Envoy gateways with version 7 firmware and higher, and is only retrieved when at least one of these channels is linked.

channeltypedescription
wattsNowNumber:PowerLatest battery power. Positive when discharging, negative when charging
stateOfChargeNumber:DimensionlessState of charge of all IQ Batteries combined
availableEnergyNumber:EnergyEnergy currently stored in the batteries

The inverter thing has the following channels:

channeltypedescription
lastReportWattsNumber:PowerLast reported power delivery
maxReportWattsNumber:PowerMaximum reported power
lastReportDateDateTimeDate of last reported power delivery
wattHoursTodayNumber:EnergyWatt hours produced today
wattHoursSevenDaysNumber:EnergyWatt hours produced the last 7 days
wattHoursLifetimeNumber:EnergyWatt hours produced over the lifetime
wattsNowNumber:PowerLatest watts produced

The wattHoursToday, wattHoursSevenDays, wattHoursLifetime and wattsNow inverter channels are only available if the Envoy gateway supports the per-device energy data endpoint.

The following channels are only available if supported by the Envoy gateway:

The relay thing has the following channels:

channeltypedescription
relayContactStatus of the relay.
line1ConnectedContactIf power line 1 is connected. If closed it's connected
line2ConnectedContactIf power line 2 is connected. If closed it's connected
line2ConnectedContactIf power line 3 is connected. If closed it's connected

The battery thing has the following channels:

channeltypeadvanceddescription
stateOfChargeNumber:DimensionlessnoState of charge of the battery
temperatureNumber:TemperaturenoTemperature of the battery
maxCellTemperatureNumber:TemperaturenoHighest temperature of the battery cells
capacityNumber:EnergyyesCapacity of the battery
sleepEnabledSwitch (Read Only)yesIf the battery sleep mode is enabled
statusStringnoThe status of the battery
communicatingSwitch (Read Only)yesIf the battery is communicating

The inverter and relay have the following additional advanced channels:

channeltypedescription
producingSwitch (Read Only)If the device is producing
communicatingSwitch (Read Only)If the device is communicating
provisionedSwitch (Read Only)If the device is provisioned
operatingSwitch (Read Only)If the device is operating

Full Example ​

Things example:

dsl
Bridge enphase:envoy:789012 "Envoy" [ serialNumber="12345789012" ] {
  Things:
    inverter 123456 "Enphase Inverter 123456" [ serialNumber="789012123456" ]
    inverter 223456 "Enphase Inverter 223456" [ serialNumber="789012223456" ]
    battery 323456 "Enphase Battery 323456" [ serialNumber="789012323456" ]
}

Items example:

dsl
Number:Power  envoyWattsNow          "Watts Now [%d %unit%]"          { channel="enphase:envoy:789012:production#wattsNow" }
Number:Energy envoyWattHoursToday    "Watt Hours Today [%d %unit%]"   { channel="enphase:envoy:789012:production#wattHoursToday" }
Number:Energy envoyWattHours7Days    "Watt Hours 7 Days [%.1f kWh]"   { channel="enphase:envoy:789012:production#wattHoursSevenDays" }
Number:Energy envoyWattHoursLifetime "Watt Hours Lifetime [%.1f kWh]" { channel="enphase:envoy:789012:production#wattHoursLifetime" }

Number:Power  i1LastReportWatts    "Last Report [%d %unit%]"                          { channel="enphase:inverter:789012:123456:lastReportWatts" }
Number:Power  i1MaxReportWatts     "Max Report [%d %unit%]"                           { channel="enphase:inverter:789012:123456:maxReportWatts" }
DateTime      i1LastReportDate     "Last Report Date [%1$tY-%1$tm-%1$td %1$tH:%1$tM]" { channel="enphase:inverter:789012:123456:lastReportDate" }
Number:Energy i1WattHoursToday     "Watt Hours Today [%d %unit%]"                     { channel="enphase:inverter:789012:123456:wattHoursToday" }
Number:Energy i1WattHoursSevenDays "Watt Hours 7 Days [%.1f kWh]"                    { channel="enphase:inverter:789012:123456:wattHoursSevenDays" }
Number:Energy i1WattHoursLifetime  "Watt Hours Lifetime [%.1f kWh]"                   { channel="enphase:inverter:789012:123456:wattHoursLifetime" }
Number:Power  i1WattsNow           "Watts Now [%d %unit%]"                            { channel="enphase:inverter:789012:123456:wattsNow" }

Number:Power i2LastReportWatts "Last Report [%d %unit%]"                          { channel="enphase:inverter:789012:223456:lastReportWatts" }
Number:Power i21MaxReportWatts "Max Report [%d %unit%]"                           { channel="enphase:inverter:789012:223456:maxReportWatts" }
DateTime     i2LastReportDate  "Last Report Date [%1$tY-%1$tm-%1$td %1$tH:%1$tM]" { channel="enphase:inverter:789012:223456:lastReportDate" }

Number:Power         envoyBatteryPower    "Battery Power [%d %unit%]"     { channel="enphase:envoy:789012:storage#wattsNow" }
Number:Dimensionless envoyBatterySoc      "Battery SoC [%d %unit%]"       { channel="enphase:envoy:789012:storage#stateOfCharge" }
Number:Energy        envoyBatteryEnergy   "Battery Energy [%.1f kWh]"     { channel="enphase:envoy:789012:storage#availableEnergy" }

Number:Dimensionless b1StateOfCharge      "Battery SoC [%d %unit%]"       { channel="enphase:battery:789012:323456:stateOfCharge" }
Number:Temperature   b1Temperature        "Battery Temperature [%d %unit%]" { channel="enphase:battery:789012:323456:temperature" }