ComfoAir Binding ​

This binding allows to monitor and control Zehnder ComfoAir serial controlled ventilation systems via RS232 serial connection. Though the binding is developed based on the protocol description for Zehnder ComfoAir devices it should also work for mostly identical systems from different manufacturers, like StorkAir WHR930, Wernig G90-380 and Paul Santos 370 DC. It was also successfully tested on a Wernig G90-160.

NOTE: This binding does not work with the ComfoAir Q-series (e.g. Q350 or Q450). These ventilation units use a CAN bus for communication and a different protocol.

Limitations ​

  • Either the ComfoAir binding or the CCEase Comfocontrol can be active, but not together.
  • You must implement auto mode by yourself with rules, but it is more powerful.

Prerequisites ​

Computer communication between ComfoAir device and openHAB via RS232 connection has to be set up. The connection should be made with a 3-wire cable connecting pins: GND, TX, RX of RS232 sockets, but RX and TX pins should be crossed (TX of ComfoAir to RX of PC, RX of ComfoAir to TX of PC).

Serial Port Access Rights ​

  • Take care that the user that runs openHAB has rights to access the serial port
  • On Ubuntu/Debian based systems (incl. openHABian) that usually means adding the user (e.g. openhab) to the group "dialout", i.e.
bash
sudo usermod -a -G dialout openhab

Supported Things ​

The binding supports thing types for different device types. They only differ in the available channels, where the generic comfoair thing type supports all available channels. If there is no thing type that matches your specific device you can safely choose the comfoair type.

Thing Type IDDescription
comfoairA ComfoAir ventilation system connected via RS232 serial connection.
WHR930Thing type restricted to the data points available for the StorkAir WHR930.

Discovery ​

Discovery is not supported.

Thing Configuration ​

For the thing creation, the appropriate serial port has to be set.

ParameterValuesDefault
serialPort/dev/ttyUSB0, COM1, etc.-
refreshIntervalRefresh interval in seconds (10...65535)60

Channels ​

The ComfoAir binding supports the following channels.

Channel IDItem TypeLabelDescriptionRead OnlyAdvanced
Binding Control
bindingControl#activateSwitchActivate Binding ControlActivate (control through openHAB) or deactivate (return control to CCEase) binding controlfalseno
Ventilation Values
ventilation#fanLevelNumberFan LevelFan levelfalseno
ventilation#fanOut0NumberFan Out Level 0 (away)Fan level 0 performance (%) of outgoing fanfalseyes
ventilation#fanOut1NumberFan Out Level 1Fan level 1 performance (%) of outgoing fanfalseyes
ventilation#fanOut2NumberFan Out Level 2Fan level 2 performance (%) of outgoing fanfalseyes
ventilation#fanOut3NumberFan Out Level 3Fan level 3 performance (%) of outgoing fanfalseyes
ventilation#fanIn0NumberFan In Level 0 (away)Fan level 0 performance (%) of incoming fanfalseyes
ventilation#fanIn1NumberFan In Level 1Fan level 1 performance (%) of incoming fanfalseyes
ventilation#fanIn2NumberFan In Level 2Fan level 2 performance (%) of incoming fanfalseyes
ventilation#fanIn3NumberFan In Level 3Fan level 3 performance (%) of incoming fanfalseyes
ventilation#fanInPercentNumberFan In (%)Current relative speed (%) of incoming fanfalseyes
ventilation#fanOutPercentNumberFan Out (%)Current relative speed (%) of outgoing fantrueyes
ventilation#fanInRPMNumber:FrequencyFan In (rpm)Current absolute speed (rpm) of incoming fantrueyes
ventilation#fanOutRPMNumber:FrequencyFan Out (rpm)Current absolute speed (rpm) of outgoing fantrueyes
Temperature Values
temperatures#targetTemperatureNumber:TemperatureTarget TemperatureTarget (comfort) temperaturefalseno
temperatures#outdoorTemperatureInNumber:TemperatureOutdoor Temperature IncomingIntake air temperature (outside)trueyes
temperatures#outdoorTemperatureOutNumber:TemperatureOutdoor Temperature OutgoingOutlet air temperature (outside)trueyes
temperatures#indoorTemperatureInNumber:TemperatureIndoor Temperature IncomingInlet air temperature (inside)trueyes
temperatures#indoorTemperatureOutNumber:TemperatureIndoor Temperature OutgoingUptake air temperature (inside)trueyes
temperatures#isT1SensorSwitchSensor T1 AvailableAvailability of temperature sensor T1 (outdoor in)trueyes
temperatures#isT2SensorSwitchSensor T2 AvailableAvailability of temperature sensor T2 (indoor in)trueyes
temperatures#isT3SensorSwitchSensor T3 AvailableAvailability of temperature sensor T3 (indoor out)trueyes
temperatures#isT4SensorSwitchSensor T4 AvailableAvailability of temperature sensor T4 (outdoor out)trueyes
temperatures#isEWTSensorSwitchGHX Sensor AvailableAvailability of geothermal heat exchanger temperature sensortrueyes
temperatures#isHeaterSensorSwitchHeater Sensor AvailableAvailability of heater temperature sensortrueyes
temperatures#isCookerhoodSensorSwitchCookerhood Sensor AvailableAvailability of cookerhood temperature sensortrueyes
temperatures#ewtTemperatureNumber:TemperatureGHX TemperatureTemperature of geothermal heat exchanger sensortrueyes
temperatures#heaterTemperatureNumber:TemperatureHeater TemperatureTemperature of heater sensortrueyes
temperatures#cookerhoodTemperatureNumber:TemperatureCookerhood TemperatureTemperature of cookerhood sensortrueyes
Uptimes
times#level0TimeNumber:TimeLevel 0 durationUptime at level 0 (away)trueyes
times#level1TimeNumber:TimeLevel 1 durationUptime at level 1trueyes
times#level2TimeNumber:TimeLevel 2 durationUptime at level 2trueyes
times#level3TimeNumber:TimeLevel 3 durationUptime at level 3trueyes
times#freezeTimeNumber:TimeAntifrost DurationUptime of antifrosttrueyes
times#preheaterTimeNumber:TimePreheater DurationUptime of preheatertrueyes
times#bypassTimeNumber:TimeBypass DurationHours of bypass opentrueyes
times#filterHoursNumber:TimeFilter DurationUptime of the filtertrueno
Menu P1: Control States
menuP1#menu20ModeSwitchMenu 20 Mode (P10)State of menu 20 mode (P10)trueyes
menuP1#menu21ModeSwitchMenu 21 Mode (P11)State of menu 21 mode (P11)trueyes
menuP1#menu22ModeSwitchMenu 22 Mode (P12)State of menu 22 mode (P12)trueyes
menuP1#menu23ModeSwitchMenu 23 Mode (P13)State of menu 23 mode (P13)trueyes
menuP1#menu24ModeSwitchMenu 24 Mode (P14)State of menu 24 mode (P14)trueyes
menuP1#menu25ModeSwitchMenu 25 Mode (P15)State of menu 25 mode (P15)trueyes
menuP1#menu26ModeSwitchMenu 26 Mode (P16)State of menu 26 mode (P16)trueyes
menuP1#menu27ModeSwitchMenu 27 Mode (P17)State of menu 27 mode (P17)trueyes
menuP1#menu28ModeSwitchMenu 28 Mode (P18)State of menu 28 mode (P18)trueyes
menuP1#menu29ModeSwitchMenu 29 Mode (P19)State of menu 29 mode (P19)trueyes
Menu P2: Delay Settings
menuP2#bathroomStartDelayNumber:TimeMenu P21Start delay for bathroom switch (uses minutes internally)falseyes
menuP2#bathroomEndDelayNumber:TimeMenu P22End delay for bathroom switch (uses minutes internally)falseyes
menuP2#L1EndDelayNumber:TimeMenu P23End delay for L1 switch (uses minutes internally)falseyes
menuP2#pulseVentilationNumber:TimeMenu P27Period for pulse ventilation (uses minutes internally)falseyes
menuP2#filterWeeksNumber:TimeMenu P24Usage period until filter pollution message (uses weeks internally)falseyes
menuP2#RFShortDelayNumber:TimeMenu P25End delay (RF short actuation) for ventilation level 3 (uses minutes internally)falseyes
menuP2#RFLongDelayNumber:TimeMenu P26End delay (RF long actuation) for ventilation level 3 (uses minutes internally)falseyes
menuP2#cookerhoodDelayNumber:TimeMenu P20End delay for cooker hood control (uses minutes internally)falseyes
Menu P9: Option States
menuP9#chimneyStateSwitchChimney Control StateState of the chimney controltrueyes
menuP9#bypassStateSwitchBypass StateState of the bypass (ON = open / OFF = closed)trueyes
menuP9#ewtStateSwitchGHX StateState of the geothermal heat exchanger valve (ON = open / OFF = closed)trueyes
menuP9#heaterStateSwitchHeater StateState of the heatertrueyes
menuP9#vControlStateSwitch0-10V Control StateState of the 0-10V controltrueyes
menuP9#frostStateSwitchAntifrost StateState of the antifrost controltrueyes
menuP9#cookerhoodStateSwitchCookerhood StateState of the cookerhood controltrueyes
menuP9#enthalpyStateSwitchEnthalpy StateState of the enthalpy moduletrueyes
Error States
errors#filterErrorSwitchFilter ErrorFilter fulltrueno
errors#errorsCurrentStringErrors CurrentCurrent errorstrueno
errors#errorsLastStringErrors LastLast errorstrueyes
errors#errorsPrelastStringErrors PrelastPrelast errorstrueyes
errors#errorsPrePrelastStringErrors Pre-PrelastPre-Prelast errorstrueyes
Bypass Values
bypass#bypassFactorNumberBypass FactorBypass factor valuetrueyes
bypass#bypassLevelNumberBypass LevelBypass level statetrueyes
bypass#bypassCorrectionNumberBypass CorrectionBypass correction statetrueyes
bypass#bypassSummerSwitchBypass Summer ModeBypass summer modetrueyes
Preheater Values
preheater#preheaterValveNumberPreheater ValveState of the preheater valvetrueyes
preheater#preheaterFrostProtectSwitchFrost ProtectionState of the frost protectiontrueyes
preheater#preheaterHeatingSwitchPreheaterState of the preheatertrueyes
preheater#preheaterFrostTimeNumber:TimePreheater Frost TimeFrost minutestrueyes
preheater#preheaterSafetyNumberPreheater Frost SafetyFrost safety settingtrueyes
GHX Values
ewt#ewtTemperatureLowNumber:TemperatureGHX Temperature (low)Lower temperature of the geothermal heat exchangerfalseyes
ewt#ewtTemperatureHighNumber:TemperatureGHX Temperature (high)Upper temperature of the geothermal heat exchangerfalseyes
ewt#ewtSpeedNumberGHX Speed Up (%)Speed up of the geothermal heat exchangerfalseyes
Heater Values
heater#heaterPowerNumberHeater PowerHeater power valuetrueyes
heater#heaterPowerINumberHeater Power I-parameterHeater power I-parameter valuetrueyes
heater#heaterTargetTemperatureNumber:TemperatureHeater Target TemperatureTarget temperature of the heaterfalseyes
Cookerhood Values
cookerhood#cookerhoodSpeedNumberCookerhood Speed Up (%)Speed up of the cookerhoodtrueyes
Enthalpy Values
enthalpy#enthalpyTemperatureNumber:TemperatureEnthalpy Sensor TemperatureTemperature of the enthalpy sensortrueyes
enthalpy#enthalpyHumidityNumberEnthalpy Sensor HumidityHumidity of the enthalpy sensortrueyes
enthalpy#enthalpyLevelNumberEnthalpy Sensor LevelLevel of the enthalpy sensortrueyes
enthalpy#enthalpyTimeNumber:TimeEnthalpy Sensor TimerTimer state of the enthalpy sensortrueyes
Option Settings
options#isPreheaterSwitchPreheaterPreheater option installedtrueyes
options#isBypassSwitchBypassBypass option installedtrueyes
options#recuTypeNumberComfoAir TypeType of the ComfoAir (1 = left / 2 = right)trueyes
options#recuSizeNumberComfoAir SizeSize of the ComfoAir (1 = big / 2 = small)trueyes
options#isChimneySwitchChimneyChimney option installedtrueyes
options#isCookerhoodSwitchCookerhoodCookerhood option installedtrueyes
options#isHeaterSwitchHeaterHeater option installedtrueyes
options#isEnthalpyNumberEnthalpyEnthalpy option installedtrueyes
options#isEWTNumberGeothermal Heat ExchangerGeothermal heat exchanger option installedtrueyes
options#analogPriorityNumberAnalog PriorityPriority of analog inputs for highest fan leveltrueyes
Inputs
inputs#isL1SwitchSwitchL1 SwitchAvailability of L1 step switchtrueyes
inputs#isL2SwitchSwitchL2 SwitchAvailability of L2 step switchtrueyes
inputs#isBathroomSwitchSwitchBathroom SwitchAvailability of bathroom switchtrueyes
inputs#isCookerhoodSwitchSwitchCookerhood SwitchAvailability of cookerhood switchtrueyes
inputs#isExternalFilterSwitchExternal FilterAvailability of external filtertrueyes
inputs#isWTWSwitchHeat RecoveryAvailability of heat recovery (WTW)trueyes
inputs#isBathroom2SwitchSwitchBathroom Switch 2Availability of bathroom switch 2 (luxe)trueyes
Resets
resets#filterResetNumberFilter ResetReset filter uptimefalseno
resets#errorResetNumberError ResetReset errorsfalseno
Analog Inputs [1-4]
analog[1-4]#isAnalogSwitchAnalog Input AvailabilityAvailability of analog input [1-4]falseyes
analog[1-4]#analogModeSwitchAnalog Input StateState of analog input [1-4]falseyes
analog[1-4]#analogNegativeSwitchAnalog Input Postive/NegativePostive/Negative state of analog input [1-4]falseyes
analog[1-4]#analogVoltNumber:ElectricPotentialAnalog Input Voltage LevelVoltage level of analog input [1-4]falseyes
analog[1-4]#analogMinNumberAnalog Input MinMinimum setting for analog input [1-4]falseyes
analog[1-4]#analogMaxNumberAnalog Input MaxMaximum setting for analog input [1-4]falseyes
analog[1-4]#analogValueNumberAnalog Input TargetTarget setting for analog input [1-4]falseyes
RF Input
analogRF#isRFSwitchRF Input AvailabilityAvailability of RF inputfalseyes
analogRF#RFModeSwitchRF Input StateState of RF inputfalseyes
analogRF#RFNegativeSwitchRF Input Postive/NegativePostive/Negative state of RF inputfalseyes
analogRF#RFMinNumberRF Input MinMinimum setting for RF inputfalseyes
analogRF#RFMaxNumberRF Input MaxMaximum setting for RF inputfalseyes
analogRF#RFValueNumberRF Input TargetTarget setting for RF inputfalseyes
analogRF#analogPriorityNumberAnalog PriorityPriority of controlfalseyes

Full Example ​

.things file:

dsl
Thing comfoair:comfoair:myComfoAir "ComfoAir" [serialPort="/dev/ttyUSB0", refreshInterval="60"]

.items file:

dsl
Switch comfoairControl    "Activate"     <computer> (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:bindingControl#activate"}
Number comfoairFanLevel   "Ventilation level [%d]"   <chart>  (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:ventilation#fanLevel"}
Number comfoairErrorReset   "Error reset"     <service> (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:resets#errorReset"}
Number comfoairFilterReset   "Filter reset"     <service> (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:resets#filterReset"}
Number comfoairFilterPeriod   "Filter period [%d weeks]"   <clock>  (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:menuP2#filterWeeks"}

// Messages
String  comfoairError   "Error: [%s]"   (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:errors#errorsCurrent"}
Number:Time comfoairFilterRuntime  "Filter runtime [%.0f h]" (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:times#filterHours"}

// State
Number:Temperature comfoairTargetTemperature  "Comfort temperature [%.1f °C]"   <temperature> (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:temperatures#targetTemperature"}
Number:Temperature comfoairOutdoorIncomingTemperature "Inlet air temperature [%.1f °C]"  <temperature> (ComfoAir, comfoairTemps_Chart) {channel="comfoair:comfoair:myComfoAir:temperatures#outdoorTemperatureIn"}
Number:Temperature comfoairIndoorIncomingTemperature "Supply air temperature [%.1f °C]"  <temperature> (ComfoAir, comfoairTemps_Chart) {channel="comfoair:comfoair:myComfoAir:temperatures#indoorTemperatureIn"}
Number:Temperature comfoairIndoorOutgoingTemperature "Return air temperature [%.1f °C]"  <temperature> (ComfoAir, comfoairTemps_Chart) {channel="comfoair:comfoair:myComfoAir:temperatures#indoorTemperatureOut"}
Number:Temperature comfoairOutdoorOutgoingTemperature "Exhaust air temperature [%.1f °C]"  <temperature> (ComfoAir, comfoairTemps_Chart) {channel="comfoair:comfoair:myComfoAir:temperatures#outdoorTemperatureOut"}
Number comfoairIncomingFan   "Supply capacity [%d %%]"   <fan_in> (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:ventilation#fanInPercent"}
Number comfoairOutgoingFan   "Exhaust capacity [%d %%]"   <fan_out> (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:ventilation#fanOutPercent"}
Number comfoairFanIn0    "Supply capacity - level 0 [%d %%]"  <fan_in> (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:ventilation#fanIn0"}
Number comfoairFanOut0    "Exhaust capacity - level 0 [%d %%]"  <fan_out> (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:ventilation#fanOut0"}
Switch comfoairBypassMode   "Bypass [MAP(comfoair_bypass.map):%s]"  <climate> (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:menuP9#bypassState"}
Switch comfoairGHXMode    "GHX [MAP(comfoair_on-off.map):%s]"  <climate> (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:menuP9#ewtState"}
Switch comfoairChimneyMode   "Fire programme [MAP(comfoair_on-off.map):%s]" <climate> (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:menuP9#chimneyState"}
Switch comfoairHeaterMode   "Heater [MAP(comfoair_on-off.map):%s]"  <climate> (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:menuP9#heaterState"}
Switch comfoairCookerHoodMode   "Extractor hood [MAP(comfoair_on-off.map):%s]" <climate> (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:menuP9#cookerhoodState"}
Switch comfoairEnthalpyMode   "Enthalpy [MAP(comfoair_on-off.map):%s]" <climate> (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:menuP9#enthalpyState"}
Switch comfoairFreezeMode   "Freeze [MAP(comfoair_freeze.map):%s]"  <climate> (ComfoAir)   {channel="comfoair:comfoair:myComfoAir:menuP9#frostState"}

.sitemap file:

dsl
sitemap comfoair label="ComfoAir" {
 Frame label="Main" {
  Text item=comfoairError labelcolor=[!="No Errors"="red"] valuecolor=[!="No Errors"="red"]
  Switch item=comfoairControl mappings=[OFF="CCEase", ON="Computer"]
  Switch item=comfoairErrorReset mappings=[1="Reset"]
  Switch item=comfoairFilterReset mappings=[1="Reset"]
 }
 Frame label="Control" {
  Selection item=comfoairFanLevel
  Setpoint item=comfoairTargetTemperature step=0.5 minValue=15 maxValue=28 valuecolor=["black"]
 }
 Frame label="State" {
  Text item=comfoairOutdoorIncomingTemperature valuecolor=["black"]
  Text item=comfoairOutdoorOutgoingTemperature valuecolor=["black"]
  Text item=comfoairIndoorIncomingTemperature valuecolor=["black"]
  Text item=comfoairIndoorOutgoingTemperature valuecolor=["black"]
 }
 Frame {
  Text item=comfoairIncomingFan valuecolor=["black"]
  Text item=comfoairBypassMode valuecolor=["black"]
  Text item=comfoairOutgoingFan valuecolor=["black"]
  Text item=comfoairGHXMode valuecolor=[OFF="silver", ON="black"]
  Text item=comfoairEfficiency valuecolor=["black"]
  Text item=comfoairFreezeMode valuecolor=[OFF="black", ON="red"]
  Text item=comfoairFilterRuntime_Message valuecolor=["black"]
  Text item=comfoairChimneyMode valuecolor=[OFF="silver", ON="black"]
 }
}

comfoair_bypass.map file:

text
ON=Opened
OFF=Closed
undefined=unknown
-=unknown

comfoair_on-off.map file:

text
ON=active
OFF=inactive
undefined=unknown
-=unknown

comfoair_freeze.map file:

text
ON=frozen
OFF=OK
undefined=unknown
-=unknown

Control Protocol Reference ​

For reference the protocol description used can be found here (german version only): Protokollbeschreibung Zehnder ComfoAir