# iAquaLink Binding
This binding supports:
- Any iAquaLink based pool system
- Reading auxiliary, temperature, pump, chemistry and system values
- Controlling system, auxiliary, lighting, and temperature settings
# Binding Configuration
The binding requires the iAquaLink user name and password. If you have more then one pool system registered to an account, you may optionally specify the pool serial ID/Number to use, otherwise the first pool controller will be used.
# Manual Thing Configuration
Thing iaqualink:controller:pool [ userName="user@domain.com", password="somepassword"]
# Channels
The following is a list of supported channels. Auxiliary and OneTouch channels will be dynamically added depending on what a system reports as being supported.
Auxiliary channels that are of a number type represent lighting modes (typically 0-15). Auxiliary channels that are dimmer types can set the light value in increments of 25 (0,25,50,750,100). The Auxiliary channel type will be dynamically assigned based on the controller configuration.
Heater status can be OFF (0), Enabled/ON (3), or Heating (1).
Channel Type ID | Item Type |
---|---|
status | String |
system_type | Number |
temp_scale | String |
spa_temp | Number:Temperature |
pool_temp | Number:Temperature |
air_temp | Number:Temperature |
spa_set_point | Number:Temperature |
pool_set_point | Number:Temperature |
cover_pool | Switch |
freeze_protection | Switch |
spa_pump | Switch |
pool_pump | Switch |
spa_heater | Switch |
pool_heater | Switch |
solar_heater | Switch |
spa_heater_status | Number |
pool_heater_status | Number |
solar_heater_status | Number |
spa_salinity | Number |
pool_salinity | Number |
orp | Number |
ph | Number |
onetouch_1 | Switch |
onetouch_n+1 | Switch |
aux_1 | Switch or String or Dimmer |
aux_n+1 | Switch or String or Dimmer |
# Color/Mood Auxiliary Channels
String auxiliary channels can control a variety of lighting moods/colors depending on what type of lighting system is installed. The following is a table of aux_n channel values (String) to lighting set descriptions values. The binding will automatically detect which color system is enabled and add the appropriate channel type with the following option labels. Colors can be set, but only On or Off is reported back as the current state of the channel.
String Value | jandy Color | Jandy LED Water Colors | Pentair SAm/SAL | Hayward Universal | Pentair intelliBrite |
---|---|---|---|---|---|
"off" | Off | Off | Off | Off | Off |
"on" | On | On | On | On | On |
"1" | Alpine White | Alpine White | White | Voodoo Lounge | SAM |
"2" | Sky Blue | Sky Blue | Light Green | Deep Blue Sea | Party |
"3" | Cobalt Blue | Cobalt Blue | Green | Afternoon Skies | Romance |
"4" | Caribbean Blue | Caribbean Blue | Cyan | Emerald | Caribbean |
"5" | Spring Green | Spring Green | Blue | Sangria | American |
"6" | Emerald Green | Emerald Green | Lavender | Cloud White | Cal Sunset |
"7" | Emerald Rose | Emerald Rose | Magenta | Twilight | Royal |
"8" | Magenta | Magenta | Light Magenta | Tranquility | Blue |
"9" | Garnet Red | Violet | Color Splash | Gemstone | Green |
"10" | Violet | Slow Splash | USA! | Red | |
"11" | Color Splash | Fast Splash | Mardi Gras | White | |
"12" | USA!!! | Cool Caberet | Magenta | ||
"13" | Fat Tuesday | Hold | |||
"14" | Disco Tech | Recall |
# Sample Items
Group Group_AquaLink
String AquaLinkStatus "Status [%s]" (Group_AquaLink) {channel="iaqualink:controller:pool:status"}
Switch AquaLinkBoosterPump "Booster Pump" (Group_AquaLink) {channel="iaqualink:controller:pool:aux_1"}
Switch AquaLinkPoolLight "Pool Light" (Group_AquaLink) {channel="iaqualink:controller:pool:aux_2"}
Switch AquaLinkSpaLight "Spa Light" (Group_AquaLink) {channel="iaqualink:controller:pool:aux_3"}
Switch AquaLinkVanishingEdge "Vanishing Edge" (Group_AquaLink) {channel="iaqualink:controller:pool:aux_4"}
Switch AquaLinkAllOffOneTouch "All Off" (Group_AquaLink) {channel="iaqualink:controller:pool:onetouch_1"}
Switch AquaLinkSpaOneTouch "Spa Mode" (Group_AquaLink) {channel="iaqualink:controller:pool:onetouch_2"}
Switch AquaLinkCleanOneTouch "Clean Mode" (Group_AquaLink) {channel="iaqualink:controller:pool:onetouch_3"}
Switch AquaLinkPoolOneTouch "Pool Mode" (Group_AquaLink) {channel="iaqualink:controller:pool:onetouch_4"}
Number:Temperature AquaLinkSpaTemp "Spa Temperature [%d]" (Group_AquaLink) {channel="iaqualink:controller:pool:spa_temp"}
Number:Temperature AquaLinkPoolTemp "Pool Temperature [%d]" (Group_AquaLink) {channel="iaqualink:controller:pool:pool_temp"}
Number:Temperature AquaLinkAirTemp "Air Temperature [%d]" (Group_AquaLink) {channel="iaqualink:controller:pool:air_temp"}
Number:Temperature AquaLinkSpaSetpoint "Spa Setpoint [%d]" (Group_AquaLink) {channel="iaqualink:controller:pool:spa_set_point"}
Number:Temperature AquaLinkPoolSetpoint "Pool Setpoint [%d]" (Group_AquaLink) {channel="iaqualink:controller:pool:pool_set_point"}
Switch AquaLinkSpaPump "Spa Pump" (Group_AquaLink) {channel="iaqualink:controller:pool:spa_pump"}
Switch AquaLinkPoolPump"Pool Pump" (Group_AquaLink) {channel="iaqualink:controller:pool:pool_pump"}
Number AquaLinkSpaHeaterStatus "Spa Heater [%s]" (Group_AquaLink) {channel="iaqualink:controller:pool:spa_heater_status"}
Number AquaLinkPoolHeaterStatus "Pool Heater [%s]" (Group_AquaLink) {channel="iaqualink:controller:pool:pool_heater_status"}
Switch AquaLinkSpaHeater "Spa Heater" (Group_AquaLink) {channel="iaqualink:controller:pool:spa_heater"}
Switch AquaLinkPoolHeater "Pool Heater" (Group_AquaLink) {channel="iaqualink:controller:pool:pool_heater"}